How Does Electronic Fluorinated Liquid Enable Immersion Cooling for Data Centers?

An AI server can generate more heat than air can efficiently dissipate. Immersion cooling does a different thing: suitable electronics are immersed in the dielectric fluid, and the heat is removed directly off the surface of the electronics and not through room air.

An electronic fluorinated liquid can serve as that fluid if its electrical insulation and thermal properties are suitable for the cooling system. However, it's not enough to simply place a server in a tank. The heat needs to be transferred from the chip to the coolant, through a heat exchanger, and out of the facility.

How Does Immersion Cooling Work in a Data Center?

The modified or specially designed servers are placed in an immersion tank that is filled with the coolant. The components transfer heat to the surrounding liquid, which carries it away through natural circulation, pumped flow, or boiling, depending on the design.

Typically the heat is transferred to a secondary cooling circuit via a heat exchanger. That circuit can be used to connect to dry coolers, cooling towers, or another heat rejection system of the facility. The immersion coolant does not have to come in contact with the same electronics as facility water.

Server fans can be eliminated from approved equipment designs since heat is gathered close to the components. But operators still require good heat rejection, monitoring, and sufficient gaps between densely packed boards for fluid circulation. It is important to note that proper electrical insulation will not eliminate the need for proper grounding, protective devices, or safe maintenance practices.

Single-Phase Immersion Cooling: Liquid Remains Liquid

During normal operation in a single-phase system, the heat is absorbed by the coolant without boiling. Warmer fluid is pumped into (or flows naturally to) the heat exchanger, and cooler fluid circulates around the server components.

The YBS-3283 electronic fluorinated cooling liquid is a cooling fluid recommended for server immersion and other temperature-control applications. Its product page includes information on the use of it for dielectric insulation and heat transfer. It is a potential fluid grade for engineering assessment, but it is not a certified match for every tank or server.

In this design, the designers need to compromise between flow rate, fluid viscosity, pumping energy and difference in temperature between the inlet and outlet of the tank. Good fluid properties do not prevent a local hot spot if the fluid does not circulate around the affected area.

The flow rates and/or heat-exchanger size are different depending on the system, because many of the fluorinated fluids have less volumetric heat capacity than water. Compare properties of fluids at operating temperature, not on the basis of equal volumes removing equal amount of heat.

Fluorinated fluids Equivalent to Electronic Liquid FC-3283 for Etchers

Two-Phase Immersion Cooling: Evaporation Carries Heat

A two-phase tank is a tank in which the fluid boils at the operating conditions. Some of the liquid is evaporated by the heat of the electronic surface, and the evaporated liquid is condensed on the cooled condenser, where it condenses back to a liquid. 

The YBS-7200 electronic heat-transfer fluid is rated for data center immersion refrigeration and has a published boiling point of 76°C. This does not mean that it is suitable for a specific server tank of the two-phase type, but rather that it could be evaluated. The operating pressure, component temperature, vapor containment, and material compatibility should be considered simultaneously.

Inadequate sealing of the installation can lead to vapor loss, resulting in fluid losses and potential environmental issues. Properly designed condensers and procedures for tank opening without excessive loss of fluid are also required for two-phase systems.

Single-Phase vs. Two-Phase Cooling

System feature

Single-phase

Two-phase

Coolant state Remains liquid Boils and condenses
Heat transfer route Circulation to heat exchanger Evaporation and condensation
Key equipment Pump or convection path Condenser and vapor containment
Main operating check Flow distribution and temperatures Boiling control and fluid recovery

The performance is dependent on the IT load, cooling plant, and actual power consumed to remove heat.

Which Fluid Properties Matter Most?

The ability of a material to resist the passage of an electric current under specified test conditions is indicated by its dielectric strength and resistivity. These are not guarantees: fluids may alter with time because of water or dissolved contaminants or material degradation.

The heat movement and pumping requirements are affected by thermal conductivity, specific heat, density, and viscosity. For two-phase systems, they also rely on boiling point, vapor pressure, and heat of vaporization. When comparing product sheets, the test temperature is important as well as the units.

Compatibility of materials is as crucial as fluid data. Labels, cable jackets, adhesives, connectors, and seals can soften, swell, or emit substances when immersed for extended periods of time. Even an "extremely chemically stable" coolant should be tested with a specific server bill of materials.

What Changes for Data Center Operations?

Immersion does not remove maintenance; it changes it. Staff require protocols for removing submerged boards, draining coolant into the tank, checking seals, and not allowing dust or cleaning chemicals to come in contact with the fluid. 

Tank fluid levels and leaks need to be monitored, and safe storage and fluid recovery procedures must be in place. For a 2-phase installation, vapor containment is even more critical. As part of normal operating records, operators should be monitoring the condition of the coolant, component temperatures, the pump or condenser performance, and the amount of coolant replenished.

For procurement, include initial fill, makeup fluid, recovery equipment, and disposal within lifetime cost.

Energy savings claimed should be assessed on a facility-by-facility basis. A decrease in the power of the server fan can be compensated to some extent by pumps or other cooling devices. Measure total power consumption at the same IT workload instead of calculating savings based on the coolant.

How Should a Cooling Fluid Be Qualified?

Use the list of approved fluids provided by the tank supplier and the immersion advice provided by the server manufacturer. Then ask for the technical and safety data for that fluid, the conditions of the dielectric test, materials compatibility proof, and environmental declarations that are required.

Conduct a small-scale pilot with representative servers and loading patterns. Control hot spot temperature, cooling loop performance, leakages, fluid condition, and damage to wetted materials. Record how to change hardware and replace coolant if necessary before scaling up.

The Open Compute Project offers guidance on immersion cooling hardware and material compatibility. YBS lists electronic fluorinated liquids for immersion cooling, but compatibility with a specific single-phase or two-phase system must be confirmed for the individual fluid grade. Fluorinated chemistries have varying degrees of persistence, global warming potential, and regulatory status, and these should not be the basis of a general assertion of environmental safety but should be part of the purchasing decision.

Conclusion

An electronic fluorinated liquid allows heat to be carried directly from compatible electronic components to a system that can reject the heat. Single-phase is a system in which liquid is circulated, while two-phase is an evaporation and condensation system. Both require appropriate thermal design, hardware design, and fluid management to function reliably.

YBS electronic grades of fluorinated liquids are available for investigation. The right fluid is the fluid recommended by the complete system operating requirements, tests, and maintenance plan.

prev
Industrial Lubricants: Types, Uses, Features, and Benefits
recommended for you
Get in touch with us
Jialede (JLD) Lubrication Materials

Industrial Lubrication Manufacturer.

Contact Us

Contacts: Sales Department

E-mail: info@ybslube.com

Tel: +86-13192083114

WhatsApp: +86-18934578611

ADD: Building 15, No. 142, Jinghai West Road, Chang'an Town, Dongguan City, Guangdong Province, China

Social Media
Copyright © 2026 | Dongguan Jialede Lubrication Materials Co.,Ltd Sitemap
Customer service